Know every vulnerabilitybefore it knows you.
DevGuard continuously monitors your dependencies and alerts you when CVEs like this one affect your stack — with real-time threat intelligence built for developers.
DEBIAN-CVE-2026-74509
No affected components available
In the Linux kernel, the following vulnerability has been resolved: Bluetooth: hci_sync: Fix advertising data UAFs hci_find_adv_instance() returns an adv_info pointer that is valid only while hdev->lock is held. The advertising command-sync paths perform instance lookups without that lock and, in some cases, retain the pointer while waiting for a controller response. An advertising termination event can therefore interleave as follows: hci_cmd_sync_work hci_rx_work hci_find_adv_instance() __hci_cmd_sync_status() wait for controller reply hci_dev_lock() hci_remove_adv_instance() kfree(adv) adv->scan_rsp_changed = false KASAN reported: BUG: KASAN: slab-use-after-free in hci_set_ext_scan_rsp_data_sync+0x2e1/0x300 Write of size 1 at addr ffff88810a45d21d by task kworker/u17:0/88 Workqueue: hci0 hci_cmd_sync_work Call Trace: hci_set_ext_scan_rsp_data_sync+0x2e1/0x300 hci_schedule_adv_instance_sync+0x390/0x4c0 hci_cmd_sync_work+0x173/0x300 Allocated by task 87: hci_add_adv_instance+0x538/0xac0 add_advertising+0x885/0x1160 Freed by task 89: kfree+0x131/0x3c0 hci_remove_adv_instance+0x1d8/0x3b0 hci_le_ext_adv_term_evt+0x17b/0x730 Protect the instance lookup and payload construction in the extended advertising, scan response, and periodic advertising data paths. Snapshot the advertising parameters under hdev->lock, but release the lock before waiting for the controller. Clear advertising-data dirty bits before issuing their commands and restore them after a failure using a fresh lookup. Likewise, update the reported transmit power through a fresh lookup after the parameter command completes. No adv_info pointer then survives an HCI command wait.
Upload your own SBOM in CycloneDX 1.6 or higher (JSON) directly here to check your vulnerabilities.
Drag and drop some file here, or click to select
The vulnerability can be exploited over a local network, such as Wi-Fi. It is easy for an attacker to exploit this vulnerability. An attacker does not need any special privileges or access rights. No user interaction is needed for the attacker to exploit this vulnerability. The impact is confined to the system where the vulnerability exists. There is a high impact on the confidentiality of the information. There is a high impact on the integrity of the data. There is a high impact on the availability of the system.
Exploitation activity has been observed. Apply available patches or mitigations urgently.
Probability that this vulnerability will be exploited in the wild within the next 30 days.
We did not find any exploit available. Neither in GitHub repositories nor in the Exploit-Database.
- CVE-2026-74509Upstream
- EUVD-2026-59702Upstream
Browse More
Continuously monitor your dependencies and get alerted when vulnerabilities like this one affect your stack.
Checkout DevGuard