Know every vulnerabilitybefore it knows you.
DevGuard continuously monitors your dependencies and alerts you when CVEs like this one affect your stack — with real-time threat intelligence built for developers.
DEBIAN-CVE-2024-26906
No affected components available
In the Linux kernel, the following vulnerability has been resolved: x86/mm: Disallow vsyscall page read for copy_from_kernel_nofault() When trying to use copy_from_kernel_nofault() to read vsyscall page through a bpf program, the following oops was reported: BUG: unable to handle page fault for address: ffffffffff600000 #PF: supervisor read access in kernel mode #PF: error_code(0x0000) - not-present page PGD 3231067 P4D 3231067 PUD 3233067 PMD 3235067 PTE 0 Oops: 0000 [#1] PREEMPT SMP PTI CPU: 1 PID: 20390 Comm: test_progs ...... 6.7.0+ #58 Hardware name: QEMU Standard PC (i440FX + PIIX, 1996) ...... RIP: 0010:copy_from_kernel_nofault+0x6f/0x110 ...... Call Trace: <TASK> ? copy_from_kernel_nofault+0x6f/0x110 bpf_probe_read_kernel+0x1d/0x50 bpf_prog_2061065e56845f08_do_probe_read+0x51/0x8d trace_call_bpf+0xc5/0x1c0 perf_call_bpf_enter.isra.0+0x69/0xb0 perf_syscall_enter+0x13e/0x200 syscall_trace_enter+0x188/0x1c0 do_syscall_64+0xb5/0xe0 entry_SYSCALL_64_after_hwframe+0x6e/0x76 </TASK> ...... ---[ end trace 0000000000000000 ]--- The oops is triggered when: 1) A bpf program uses bpf_probe_read_kernel() to read from the vsyscall page and invokes copy_from_kernel_nofault() which in turn calls __get_user_asm(). 2) Because the vsyscall page address is not readable from kernel space, a page fault exception is triggered accordingly. 3) handle_page_fault() considers the vsyscall page address as a user space address instead of a kernel space address. This results in the fix-up setup by bpf not being applied and a page_fault_oops() is invoked due to SMAP. Considering handle_page_fault() has already considered the vsyscall page address as a userspace address, fix the problem by disallowing vsyscall page read for copy_from_kernel_nofault().
The vulnerability requires local access to the device to be exploited. It is easy for an attacker to exploit this vulnerability. An attacker needs basic access or low-level privileges. No user interaction is needed for the attacker to exploit this vulnerability. The impact is confined to the system where the vulnerability exists. There is a high impact on the availability of the system.
Exploitation attempts have been detected. Elevated vigilance and prompt remediation are advised.
Probability that this vulnerability will be exploited in the wild within the next 30 days.
We did not find any exploit available. Neither in GitHub repositories nor in the Exploit-Database.
- CVE-2024-26906Upstream
- EUVD-2024-24168Upstream
Browse More
Continuously monitor your dependencies and get alerted when vulnerabilities like this one affect your stack.
Checkout DevGuard