Know every vulnerabilitybefore it knows you.
DevGuard continuously monitors your dependencies and alerts you when CVEs like this one affect your stack — with real-time threat intelligence built for developers.
DEBIAN-CVE-2022-48814
No affected components available
In the Linux kernel, the following vulnerability has been resolved: net: dsa: seville: register the mdiobus under devres As explained in commits: 74b6d7d13307 ("net: dsa: realtek: register the MDIO bus under devres") 5135e96a3dd2 ("net: dsa: don't allocate the slave_mii_bus using devres") mdiobus_free() will panic when called from devm_mdiobus_free() <- devres_release_all() <- __device_release_driver(), and that mdiobus was not previously unregistered. The Seville VSC9959 switch is a platform device, so the initial set of constraints that I thought would cause this (I2C or SPI buses which call ->remove on ->shutdown) do not apply. But there is one more which applies here. If the DSA master itself is on a bus that calls ->remove from ->shutdown (like dpaa2-eth, which is on the fsl-mc bus), there is a device link between the switch and the DSA master, and device_links_unbind_consumers() will unbind the seville switch driver on shutdown. So the same treatment must be applied to all DSA switch drivers, which is: either use devres for both the mdiobus allocation and registration, or don't use devres at all. The seville driver has a code structure that could accommodate both the mdiobus_unregister and mdiobus_free calls, but it has an external dependency upon mscc_miim_setup() from mdio-mscc-miim.c, which calls devm_mdiobus_alloc_size() on its behalf. So rather than restructuring that, and exporting yet one more symbol mscc_miim_teardown(), let's work with devres and replace of_mdiobus_register with the devres variant. When we use all-devres, we can ensure that devres doesn't free a still-registered bus (it either runs both callbacks, or none).
The vulnerability requires local access to the device to be exploited. It is easy for an attacker to exploit this vulnerability. An attacker needs basic access or low-level privileges. No user interaction is needed for the attacker to exploit this vulnerability. The impact is confined to the system where the vulnerability exists. There is a high impact on the availability of the system.
Exploitation attempts have been detected. Elevated vigilance and prompt remediation are advised.
Probability that this vulnerability will be exploited in the wild within the next 30 days.
We did not find any exploit available. Neither in GitHub repositories nor in the Exploit-Database.
- CVE-2022-48814Upstream
- EUVD-2022-53693Upstream
Browse More
Continuously monitor your dependencies and get alerted when vulnerabilities like this one affect your stack.
Checkout DevGuard