CVE-2026-15890
The default AEAD nonce provider for the PSA Internal Trusted Storage transform module, secure_storage_its_transform_aead_get_nonce() in subsys/secure_storage/src/its/transform/aead_get.c, stores its nonce counter in unsynchronized function-local static variables (s_nonce and s_nonce_initialized). Every ITS write obtains its AES-GCM or ChaCha20-Poly1305 nonce here via secure_storage_its_transform_to_store().
Because the function held no lock, two threads calling it concurrently race on the shared statics: the initialization path (psa_generate_random() followed by memcpy()) and the non-atomic increment-then-copy path can each hand the same nonce value to two distinct encryption operations, and can lose increments so the counter repeats values it was designed never to repeat. The ITS layer (secure_storage_its_set() in subsys/secure_storage/src/its/implementation.c) performs no serialization of its own, so concurrent same-UID writes reach the racy provider directly.
Reusing a nonce with the same key under AES-GCM or ChaCha20-Poly1305 is a catastrophic AEAD failure: it leaks the XOR of the two plaintexts (ITS routinely stores secrets, including PSA persistent keys) and, for GCM, exposes the authentication key, enabling forgery of stored entries. Because the AEAD key is derived per entry UID, the security-relevant collision is two concurrent writes to the same UID both receiving the same nonce; an adversary able to read the raw backing storage can then exploit the reuse.
Both ITS store back-ends shipped with Zephyr, zms.c and the settings/NVS back-end in settings.c, are log-structured flash stores with deferred garbage collection, so an entry superseded by a rewrite remains physically present in the partition until its sector is reclaimed. Two same-UID writes that race therefore leave both ciphertexts readable in the raw image at once, which is the condition the nonce reuse needs to be exploitable. The trigger remains narrow: both built-in key providers (DEVICE_ID_HASH and ENTRY_UID_HASH) salt the derived key with the entry UID, so reuse across different UIDs is harmless, and the exposure requires an application that writes the same UID concurrently from two threads.
The fix serializes the provider with a K_MUTEX_DEFINE(s_nonce_mutex) held for the duration of nonce generation.
Upload your own SBOM in CycloneDX 1.6 or higher (JSON) directly here to check your vulnerabilities.
Drag and drop some file here, or click to select
The vulnerability requires local access to the device to be exploited. It is difficult for an attacker to exploit this vulnerability and may require special conditions. An attacker needs basic access or low-level privileges. No user interaction is needed for the attacker to exploit this vulnerability. The impact is confined to the system where the vulnerability exists. There is a high impact on the confidentiality of the information. There is a low impact on the integrity of the data.
Exploitation attempts have been detected. Elevated vigilance and prompt remediation are advised.
The exploit probability is very low. The vulnerability is unlikely to be exploited in the next 30 days.
We did not find any exploit available. Neither in GitHub repositories nor in the Exploit-Database.